4" square
Part no | Mounting height (ft) | Pole weight (lbs) | Anchor bolt diameter (in) | Bolt Circle Diameter (BCD in) | Max load @ 70 mph (ft² EPA / lbs) | Max load @ 80 mph (ft² EPA / lbs) | Max load @ 100 mph (ft² EPA / lbs) |
---|---|---|---|---|---|---|---|
SSA4-08 | 8 | 36 | 3/4 | 8-1/2 | 14 / 350 | 7 / 175 | 4 / 100 |
SSA4-10 | 10 | 43 | 3/4 | 8-1/2 | 11 / 350 | 9 / 225 | 5 / 125 |
SSA4-12 | 12 | 50 | 3/4 | 8-1/2 | 9 / 225 | 8 / 200 | 4 / 150 |
SSA4-15 | 15 | 60 | 3/4 | 8-1/2 | 7 / 175 | 7 / 150 | 3.5 / 88 |
SSA4-18 | 18 | 70 | 3/4 | 8-1/2 | 6 / 150 | 5 / 150 | 3 / 75 |
SSA4-20 | 20 | 77 | 3/4 | 8-1/2 | 5 / 125 | 4 / 150 | 2 / 50 |
5" square
Part no | Mounting height (ft) | Pole weight (lbs) | Anchor bolt diameter (in) | Bolt Circle Diameter (BCD in) | Max load @ 70 mph (ft² EPA / lbs) | Max load @ 80 mph (ft² EPA / lbs) | Max load @ 100 mph (ft² EPA / lbs) |
---|---|---|---|---|---|---|---|
SSA5-15 | 15 | 79 | 3/4 | 10-1/2 | 14 / 350 | 12 / 300 | 9 / 225 |
SSA5-18 | 18 | 92 | 3/4 | 10-1/2 | 12 / 150 | 10 / 250 | 7 / 175 |
SSA5-20 | 20 | 101 | 3/4 | 10-1/2 | 10 / 250 | 8 / 150 | 5 / 150 |
SSA5-25 | 25 | 122 | 3/4 | 10-1/2 | 6.5 / 163 | 5 / 150 | 3 / 75 |
6" square
Part no | Mounting height (ft) | Pole weight (lbs) | Anchor bolt diameter (in) | Bolt Circle Diameter (BCD in) | Max load @ 70 mph (ft² EPA / lbs) | Max load @ 80 mph (ft² EPA / lbs) | Max load @ 100 mph (ft² EPA / lbs) |
---|---|---|---|---|---|---|---|
SSA6-20 | 20 | 147 | 1 | 12 | 17 / 425 | 11 / 150 | 9 / 225 |
SSA6-25 | 25 | 180 | 1 | 12 | 14 / 350 | 11 / 150 | 6 / 150 |
SSA6-30 | 30 | 214 | 1 | 12 | 10 / 150 | 8 / 150 | 3 / 75 |
- CSA certified to C22.2 No. 206-17 (Lighting Poles) following S6-14 (Canadian Highway Bridge Design Code) with fatigue design based on AASHTO LRFDLTS1.
- Welding conforms to CSA and CWB W47 and W59.
- Hinged bases may be available for above; please consult Dynapole for details.
- Maximum EPA and weight allowances are based on side-mounted luminaires and/or brackets only. Consult Dynapole for top-mounted luminaire allowances
- Complete with 1 fixture tenon or top cap and 1 fixture drilling.
- Complete with gasketed hand hole cover, ground clip, galvanized steel anchor bolts and base cover.
- Includes minimum 2" x 5" hand hole opening.
- Pole weight includes the pole shaft and base plate casting only.
- The base plate is provided with bolt holes 1/8" to 1/4" larger than the anchor bolt diameter.
- Standard finishes are black or bronze (brown) polyester powder.